ZGS13 Pad Mounted Transformer
Rated main circuit current
Rated current
The rated voltage
Application
ZGS11 series pad mounted transformer (commonly known as the American box), its structure is "product" word structure, transformer with high and low pressure equipment is an organic whole repeatedly mutually close, among them, the transformer three sides exposed in the air, cooling condition, and with high and low voltage separation equipment shell, to facilitate maintenance.
Transformer USES the chip of oil tank, oil free pillow, fully enclosed S11 series of oil-immersed transformer, high and low pressure casing, tap-changer, oil level indicator, pressure release valve, drain valve end plate are hold in hyperbaric chamber, such as ontology, reasonable position, convenient for observation, operation.
The high pressure cabin and the low pressure cabin are separated by steel plate. The transformer of high pressure and low pressure cabin is relatively independent, and it keeps a complete box. It is compact, small in size and light in weight. Install the power distribution switchgear on the high and low voltage side.

Technical specification
Cooling conditions: air cooling
Altitude: ≤1000m
Ambient temperature: outdoor ambient temperature is not higher than 40 °C, not lower than -45 °C; monthly average temperature does not exceed 30 °C, annual average temperature does not exceed 30 °C, annual average temperature does not exceed 20 °C
Relative Humidity: At 25°C, the relative humidity of the air does not exceed 95% and the monthly average is not more than 90%
Earthquake resistance level: horizontal acceleration is not more than 0.3m/s2, vertical acceleration is not more than 0.15m/s2
Surroundings: The installation environment should be free from obvious contamination, explosive, corrosive gases and dust
Installation site: It should be free from severe vibration and shock, and it must be installed on concrete platforms or other flat, solid platforms.
* When the above normal use conditions do not meet the requirements for use, the user negotiates with the manufacturer.

Download
點擊下載 附件:ZGS13係列組合(hé)式(shì)變壓器.pdf    大小: 913KB 下載:
Leave a message
Under construction...
Committed to technological innovation
Make electricity supply more reliable, make electricity use more secure.
Product quotation consultation
A free consultation
hotline:400 8099 777

CONTACT US

WeChat

Jubang science and technology park, wei16 road, leqing economic development zone, zhejiang province

  • phones:+86577 62799786
  • fax:+86577 62799771
  • Email:jubanggroup@163.com
  • web:www.tr-klk.com
  • Customer service hotline:400 8099 777